Volvo Penta

Prime Power
1500 RPM (50 Hz)
GENSET MODEL ENGINE MODEL 3 Ph. 415 V, 0.8 PF
BHP kVA kWe
SV250 TAD 734GE 306 250 200
SV280 TAD 940GE 344 280 224
SV320 TAD 941GE 401 320 256
SV380 TAD 1241GE 452 380 304
SV415 TAD 1242GE 494 415 332
SV500 TAD 1641GE 600 500 400
SV575 TAD 1642GE 675 575 460
SV630 TAD 1643GE 752 630 504

 

1800 RPM (60 Hz)
GENSET MODEL ENGINE MODEL 3 Ph. 380-460V, 0.8 PF
BHP kVA kWe
SV250E TAD 734GE 321 250 200
SV285E TAD 940GE 366 285 228
SV350E TAD 941GE 437 350 280
SV415E TAD 1241GE 499 415 332
SV460E TAD 1242GE 558 460 368
SV575E TAD 1641GE 685 575 46
SV625E TAD 1642GE 749 625 500
SV700E TAD 1643GE 836 700 560


Maximum Standby Power

1500 RPM (50 Hz)
GENSET MODEL ENGINE MODEL 3 Ph. 415 V, 0.8 PF
BHP kVA kWe
SV280(S) TAD 734GE 340 280 224
SV320(S) TAD 940GE 377 320 256
SV360(S) TAD 941GE 439 360 288
SV415(S) TAD 1241GE 494 415 332
SV460(S) TAD 1242GE 541 460 368
SV550(S) TAD 1641GE 658 550 440
SV625(S) TAD 1642GE 744 625 500
SV700(S) TAD 1643GE 834 700 560

800 RPM (60 Hz)
GENSET MODEL ENGINE MODEL 3 Ph. 380-460V. 0.8 PF
BHP kVA kWe
SV285E(S) TAD 734GE 357 285 228
SV320E(S) TAD 940GE 400 320 256
SV380E(S) TAD 941GE 477 380 304
SV460E(S) TAD 1241GE 547 460 368
SV500E(S) TAD 1242GE 611 500 400
SV650E(S) TAD 1641GE 768 650 520
SV700E(S) TAD 1642GE 821 700 560
SV750E(S) TAD 1643GE 917 750 600

Note : 230 V, 3 phase, 60Hz systems also available on request

* Volvo Powered DG Sets ( Exclusively for Export)

1500 RPM (50 Hz)
GENSET MODEL ENGINE MODEL 3 Ph. 415 V, 0.8 PF
BHP kVA kWe
SV 85 TAD 530GE 109 85 68
SV 100 TAD 531GE 125 100 80
SV 130 TAD 532GE 158 130 104
SV 150 TAD 731GE 187 150 120
SV 180 TAD 732GE 224 180 144
SV 200 TAD 733GE 246 200 160

 

1800 RPM (60 Hz)
GENSET MODEL ENGINE MODEL 3 Ph. 380-460V. 0.8 PF
BHP kVA kWe
SV 90E TAD 530GE 116 90 72
SV 110E TAD 531GE 136 110 88
SV 140E TAD 532GE 166 140 112
SV 160E TAD 731GE 200 160 128
SV 200E TAD 732GE 250 200 160
SV 225E TAD 733GE 275 225 180

Note: The above ratings are only for Exports outside India. DG sets of above ratings at 380/220 V, 3 phase
60Hz, 0.8 PF are also available


Power Standards
Engine Performance corresponds to ISO 3046, BS 5514, DIN 6271. The technical data applies to an engine operation on a fuel with a calorific value of 42.7 MJ/Kg (18360 BTU/lb) and a density of 0.84 Kg/Liter (7.01 lb/US gal.). Engine speed governing in accordance with ISO 3046/IV, Class A1 and ISO 8528 Class G3. The Engines may be operated upto 1500m altitude and 0 deg C. ambient temperature without deration. No deration on account of Relative Humidity. Power Output is guaranteed within 0 to +2% at rated ambient conditions.


Rating Guidelines

PRIME POWER rating corresponds to ISO Standard Power for supplying electrical power at variable load for an unlimited number of hours instead of commercially purchased power. A 10% overload capability available with this rating for one hour in every twelve hours.

MAXIMUM STANDBY POWER rating corresponds to ISO Fuel Stop Power. It is applicable for supplying standby electrical power at variable load in areas with well established electrical networks, in the event of power failure. No overload capability available with this rating.

Generators, Gensets, D.G. Sets, UPS, Inverters, Lift Inveters, Stabilizers, Control Panels, Sound Proof Acostic Enclosures, Trolley for Mobile Generators, Erection commissoning, Servicing & Annual Maintance Contract for all type of Generators & UPS